Under 40 CFR 141.28, samples count toward compliance with the listed sections only if a laboratory certified by EPA or the State analyzed them. Measurements of alkalinity, disinfectant residual, orthophosphate, pH, silica, temperature and turbidity are the exception: any person acceptable to the State may perform them. For lead and copper, 141.89 sets a similar split (alkalinity, orthophosphate, pH and silica by any person acceptable to the State; lead and copper only by certified laboratories) and adds what a laboratory must do to be certified.

Drinking water operatorExplainerPublished

Fact-checked against official sources · Last checked

Card reading Drinking water operator, Explainer: Who can analyze your water samples? 40 CFR 141.28. eCFR, Nov 16, 2026
Image: goraedu · Own work

A drinking water operator may collect many samples, but a result counts for compliance under the sections listed in 141.28 only if the right person analyzed the sample. The federal rule is short: 40 CFR 141.28, "Certified laboratories", in Subpart C of the National Primary Drinking Water Regulations. This explainer reads it, and the matching lead and copper rule, as they stand in the eCFR (current to November 12, 2026). Nothing here describes a rule change.

Which results must come from a certified laboratory?

141.28(a) states: "For the purpose of determining compliance with §§ 141.21 through 141.27, 141.40, 141.74, 141.89, 141.402, 141.901, and 141.902, samples may be considered only if they have been analyzed by a laboratory certified by EPA or the State except that measurements of alkalinity, disinfectant residual, orthophosphate, pH, silica, temperature, and turbidity may be performed by any person acceptable to the State."

The sections it names, by their eCFR headings, are:

Section(s)eCFR heading
141.21Coliform sampling
141.22Turbidity sampling and analytical requirements
141.23Inorganic chemical sampling and analytical requirements
141.24Organic chemicals, sampling and analytical requirements
141.25 and 141.26Analytical methods for radioactivity; monitoring frequency and compliance requirements for radionuclides in community water systems
141.27Alternate analytical techniques
141.40Monitoring requirements for unregulated contaminants (Subpart E, Special Regulations, Including Monitoring)
141.74Analytical and monitoring requirements (Subpart H, Filtration and Disinfection)
141.89Analytical methods (Subpart I, Control of Lead and Copper)
141.402Ground water source microbial monitoring and analytical methods (Subpart S, Ground Water Rule)
141.901 and 141.902Analytical requirements; monitoring requirements (Subpart Z, Control of Per- and Polyfluoroalkyl Substances (PFAS))

Rows without a subpart named are in Subpart C. Any compliance result under those sections, other than the seven measurements listed below, has to come from a laboratory certified by EPA or the State.

Which measurements can a non-laboratory person take?

The same sentence lists seven: "alkalinity, disinfectant residual, orthophosphate, pH, silica, temperature, and turbidity." For these, the rule does not require a certified laboratory. It requires "any person acceptable to the State." That is the State's decision; 141.28 does not say who the State must accept or how.

What about lead and copper?

141.89(a)(1) sets a similar split for the lead and copper rule, naming four of the seven measurements: "Analyses for alkalinity, orthophosphate, pH, and silica may be performed by any person acceptable to the State. Analyses under this section for lead and copper shall only be conducted by laboratories that have been certified by EPA or the State."

It also lists what a laboratory must do to be certified for lead and copper. It must "Analyze Performance Evaluation samples, which include lead and copper, provided by or acceptable to EPA or the State at least once a year by each method for which the laboratory desires certification", meet acceptance limits (for lead, "±30 percent of the actual amount in the Performance Evaluation sample when the actual amount is greater than or equal to 0.005 mg/L"; for copper, "±10 percent" at or above 0.050 mg/L), achieve a lead method detection limit of 0.001 mg/L, and "Be currently certified by EPA or the State" to perform those analyses.

Can the State take its own samples?

Yes. 141.28(b) states: "Nothing in this part shall be construed to preclude the State or any duly designated representative of the State from taking samples or from using the results from such samples to determine compliance by a supplier of water with the applicable requirements of this part."

Who certifies the laboratories?

To receive primary enforcement responsibility (primacy), a State must meet conditions that include a laboratory certification program, unless EPA's Administrator waives it as 142.10(b)(3) allows. 40 CFR 142.10(b)(3)(i) lists "The establishment and maintenance of a State program for the certification of laboratories conducting analytical measurements of drinking water contaminants pursuant to the requirements of the State primary drinking water regulations". 142.10(b)(4) adds "Assurance of the availability to the State of laboratory facilities certified by the Administrator and capable of performing analytical measurements of all contaminants specified in the State primary drinking water regulations."

The federal text does not list which laboratories are certified in your state. Ask your state's drinking water program which laboratories it has certified.

What this means for operators

  • Send compliance samples under the listed sections to a laboratory certified by EPA or the State.
  • The seven measurements listed in 141.28(a), such as pH, temperature, turbidity and disinfectant residual, may be performed by any person acceptable to the State; check your state's rules for who that is.
  • State regulations must be "no less stringent than" the federal rules (40 CFR 142.10(a)) and may differ in detail; this post covers only the federal text.

Study with goraedu

Our total coliform study guide and lead and copper study guide cover the monitoring rules these samples serve, and the filtration and disinfection study guide covers who measures turbidity and disinfectant residual under 141.74. See every topic on the drinking water operator hub. Our questions are our own, written from the regulation.