What Does OSHA Require on a Compressed Air Receiver? Drain Valve, Gage and Safety Valves Under 29 CFR 1910.169

OSHA's general industry rule for compressed air receivers, 29 CFR 1910.169, requires a drain pipe and valve at the lowest point of every receiver, completely draining it frequently enough to prevent excessive liquid, an indicating pressure gage that is readily visible, one or more spring-loaded safety valves, no valve of any type between the receiver and its safety valves, and testing of safety valves frequently and at regular intervals. Receivers may not be buried underground or put in an inaccessible place.

OSHA general industry safetyExplainerPublished

Fact-checked against official sources · Last checked

Card reading OSHA general industry safety, Explainer: Air receivers: drain, gage, safety valves, 29 CFR 1910.169. eCFR, Nov 26, 2026
Image: goraedu · Own work

An air receiver is a tank that holds compressed air. OSHA's general industry rules cover these tanks in 29 CFR 1910.169, "Air receivers," in Subpart M (Compressed Gas and Compressed Air Equipment). This explainer answers one practical question: what must an air receiver have, and what must be done to keep it in working order? It reads the section in the eCFR (text current to November 24, 2026). It is an explainer, not a rule change.

Which equipment does the section cover?

Under 1910.169(a)(1), the section "applies to compressed air receivers, and other equipment used in providing and utilizing compressed air for performing operations such as cleaning, drilling, hoisting, and chipping."

The same paragraph sets three limits. The section "does not deal with the special problems created by using compressed air to convey materials nor the problems created when men work in compressed air as in tunnels and caissons." It also "is not intended to apply to compressed air machinery and equipment used on transportation vehicles such as steam railroad cars, electric railway cars, and automotive equipment."

How must a receiver be built?

1910.169(a)(2)(i) states that "All new air receivers installed after the effective date of these regulations shall be constructed in accordance with the 1968 edition of the A.S.M.E. Boiler and Pressure Vessel Code Section VIII," which is incorporated by reference in 1910.6. Under (a)(2)(ii), "All safety valves used shall be constructed, installed, and maintained in accordance with the A.S.M.E. Boiler and Pressure Vessel Code, Section VIII Edition 1968."

Where can a receiver be installed?

1910.169(b)(1) requires that receivers "be so installed that all drains, handholes, and manholes therein are easily accessible." It adds: "Under no circumstances shall an air receiver be buried underground or located in an inaccessible place."

Does the tank need a drain, and how often is it drained?

Yes. 1910.169(b)(2) states: "A drain pipe and valve shall be installed at the lowest point of every air receiver to provide for the removal of accumulated oil and water." Automatic traps are allowed but do not replace the valve: "Adequate automatic traps may be installed in addition to drain valves."

The rule does not set a fixed number of days. It states: "The drain valve on the air receiver shall be opened and the receiver completely drained frequently and at such intervals as to prevent the accumulation of excessive amounts of liquid in the receiver."

What gage and safety valves are required?

1910.169(b)(3)(i) states: "Every air receiver shall be equipped with an indicating pressure gage (so located as to be readily visible) and with one or more spring-loaded safety valves." The same paragraph sets how much the valves must relieve: their "total relieving capacity" must "prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent."

Three more rules protect those valves:

  • Nothing in between: "No valve of any type shall be placed between the air receiver and its safety valve or valves" (1910.169(b)(3)(ii)).
  • Hard to defeat: "Safety appliances, such as safety valves, indicating devices and controlling devices, shall be constructed, located, and installed so that they cannot be readily rendered inoperative by any means, including the elements" (1910.169(b)(3)(iii)).
  • Testing: "All safety valves shall be tested frequently and at regular intervals to determine whether they are in good operating condition" (1910.169(b)(3)(iv)). As with draining, the section does not give a fixed interval.

Quick list

  • Drains, handholes and manholes easily accessible; never buried or in an inaccessible place.
  • Drain pipe and valve at the lowest point; drained completely, frequently enough to prevent excessive liquid.
  • Readily visible indicating pressure gage.
  • One or more spring-loaded safety valves sized so pressure cannot exceed the maximum allowable working pressure by more than 10 percent.
  • No valve of any type between the receiver and its safety valves.
  • Safety valves tested frequently and at regular intervals.

What this means for study

Section 1910.169 is not in our general industry study guides. The section is short, so its wording (lowest point, readily visible gage, spring-loaded safety valves, the 10 percent limit, no valve in between) is worth reading in full in the eCFR linked below. Every general industry topic we cover is on our OSHA general industry page.

goraedu is independent and is not affiliated with or endorsed by OSHA or any government agency.