goraedu

Drinking water maximum contaminant levels study guide

Subpart G of 40 CFR Part 141 sets the federal maximum contaminant levels (MCLs) for organic, inorganic, microbiological, disinfection byproduct and radionuclide contaminants, and the maximum residual disinfectant levels (MRDLs) for chlorine, chloramines and chlorine dioxide. This guide sets out what the rule text states on which systems each limit covers, the units and the compliance basis, the effective and compliance dates, and the best available technologies (BAT) EPA lists. The PFAS entries in 141.61(c)(2) have an effective date of April 26, 2029. Monitoring and analytical methods sit in other subparts and are not covered. Your State drinking water program may have its own requirements, so check them too. Every point links to the regulation and quotes its exact words.

Fact-checked against official sources · Last checked

Effective dates and who the limits cover

  • Under 141.60(a)(1), the volatile organic MCLs in 141.61(a)(1) through (a)(8) took effect on January 9, 1989.

    “The effective date for paragraphs (a)(1) through (a)(8) of § 141.61 is January 9, 1989.”

    40 CFR 141.60, Effective dates

  • Under 141.60(a)(4), the PFAS entries in 141.61(c)(2)(i) through (vii) (the PFAS MCLs and the Hazard Index HBWCs) have an effective date of April 26, 2029.

    “The effective date for § 141.61(c)(2)(i) through (vii) is April 26, 2029.”

    40 CFR 141.60, Effective dates

  • Under 141.60(b)(1), the fluoride MCL in 141.62(b)(1) took effect on October 2, 1987.

    “The effective date of paragraph (b)(1) of § 141.62 is October 2, 1987.”

    40 CFR 141.60, Effective dates

  • Under 141.60(b)(4), the arsenic MCL in 141.62(b)(16) took effect on January 23, 2006.

    “The effective date for § 141.62(b)(16) is January 23, 2006.”

    40 CFR 141.60, Effective dates

  • The volatile organic contaminant MCLs in 141.61(a) apply to community and non-transient, non-community water systems.

    “The following maximum contaminant levels for volatile organic contaminants apply to community and non-transient, non-community water systems.”

    40 CFR 141.61, Maximum contaminant levels for organic contaminants

  • The synthetic organic contaminant MCLs in 141.61(c)(1) and (2), including the PFAS MCLs, apply to community water systems and non-transient, non-community water systems.

    “The following maximum contaminant levels (MCLs) in paragraphs (c)(1) and (2) of this section for synthetic organic contaminants apply to community water systems and non-transient, non-community water systems”

    40 CFR 141.61, Maximum contaminant levels for organic contaminants

  • The inorganic MCLs in 141.62(b)(2)–(6), (b)(10) and (b)(11)–(16) apply to community water systems and non-transient, non-community water systems.

    “The maximum contaminant levels for inorganic contaminants specified in paragraphs (b) (2)-(6), (b)(10), and (b) (11)-(16) of this section apply to community water systems and non-transient, non-community water systems.”

    40 CFR 141.62, Maximum contaminant levels for inorganic contaminants

  • The nitrate, nitrite and total nitrate and nitrite MCLs in 141.62(b)(7) through (9) also apply to transient non-community water systems.

    “The maximum contaminant levels specified in (b)(7), (b)(8), and (b)(9) of this section apply to community water systems; non-transient, non-community water systems; and transient non-community water systems.”

    40 CFR 141.62, Maximum contaminant levels for inorganic contaminants

Not covered here

Maximum contaminant level goals (MCLGs) and MRDLGs are not covered here. Monitoring frequencies, sampling locations and analytical methods are in other subparts of Part 141 and are not covered here. We only write what an official source states, so study these parts with your certifying program's materials.

Organic contaminants and PFAS

Not covered here

The PFAS MCLs and HBWCs in 141.61(c)(2) have an effective date of April 26, 2029 (141.60(a)(4)); PFAS monitoring and other PFAS requirements outside Subpart G are not covered. This guide follows the eCFR text as of Nov 3, 2026. We only write what an official source states, so study these parts with your certifying program's materials.

Inorganic contaminants

Not covered here

The lead and copper action levels are in Subpart I, not Subpart G, and are not covered here. 141.62(b) also limits the fluoride MCL in (b)(1) to community water systems; see the linked section for that sentence. We only write what an official source states, so study these parts with your certifying program's materials.

Microbiological contaminants

  • Until March 31, 2016, the total coliform MCL was based on presence or absence of total coliforms in a sample, not coliform density.

    “Until March 31, 2016, the total coliform MCL is based on the presence or absence of total coliforms in a sample, rather than coliform density.”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

  • Under that pre-2016 rule, a system collecting at least 40 samples a month complied if no more than 5.0 percent of the month's samples were total coliform-positive.

    “For a system that collects at least 40 samples per month, if no more than 5.0 percent of the samples collected during a month are total coliform-positive, the system is in compliance with the MCL for total coliforms.”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

  • Beginning April 1, 2016, a system complies with the E. coli MCL for samples taken under subpart Y unless one of the conditions in 141.63(c)(1) through (4) occurs.

    “Beginning April 1, 2016, a system is in compliance with the MCL for E. coli for samples taken under the provisions of subpart Y of this part unless any of the conditions identified in paragraphs (c)(1) through (c)(4) of this section occur.”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

  • Two of the conditions are an E. coli-positive repeat sample following a total coliform-positive routine sample, and a total coliform-positive repeat sample following an E. coli-positive routine sample.

    “(1) The system has an E. coli-positive repeat sample following a total coliform-positive routine sample. (2) The system has a total coliform-positive repeat sample following an E. coli-positive routine sample.”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

  • The other two conditions are failing to take all required repeat samples after an E. coli-positive routine sample, and failing to test for E. coli when any repeat sample tests positive for total coliform.

    “(3) The system fails to take all required repeat samples following an E. coli-positive routine sample. (4) The system fails to test for E. coli when any repeat sample tests positive for total coliform.”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

  • For public notification under subpart Q, a violation of the E. coli MCL may pose an acute risk to health.

    “For purposes of the public notification requirements in subpart Q of this part, violation of the MCL may pose an acute risk to health.”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

  • Beginning April 1, 2016, a public water system must determine E. coli MCL compliance for each month in which it is required to monitor for total coliforms.

    “Beginning April 1, 2016, a public water system must determine compliance with the MCL for E. coli in paragraph (c) of this section for each month in which it is required to monitor for total coliforms.”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

  • Among the best technology, treatment techniques or other means 141.63(e) lists for coliform MCL compliance are keeping a disinfectant residual throughout the distribution system and proper distribution system maintenance, including cross connection control and continual positive water pressure in all parts of the system.

    “(2) Maintenance of a disinfectant residual throughout the distribution system; (3) Proper maintenance of the distribution system including appropriate pipe replacement and repair procedures, main flushing programs, proper operation and maintenance of storage tanks and reservoirs, cross connection control, and continual maintenance of positive water pressure in all parts of the distribution system;”

    40 CFR 141.63, Maximum contaminant levels (MCLs) for microbiological contaminants

Not covered here

Routine and repeat sampling rules for coliforms are in Subpart Y and are not covered here. We only write what an official source states, so study these parts with your certifying program's materials.

Disinfection byproducts

  • 141.64(a) sets the bromate MCL at 0.010 mg/L and the chlorite MCL at 1.0 mg/L.

    “Bromate 0.010 Chlorite 1.0”

    40 CFR 141.64, Maximum contaminant levels for disinfection byproducts

  • For CWSs and NTNCWSs, subpart H systems serving 10,000 or more had to comply with the bromate and chlorite MCLs beginning January 1, 2002; smaller subpart H systems and systems using only ground water not under the direct influence of surface water, beginning January 1, 2004.

    “Compliance dates for CWSs and NTNCWSs. Subpart H systems serving 10,000 or more persons must comply with this paragraph (a) beginning January 1, 2002. Subpart H systems serving fewer than 10,000 persons and systems using only ground water not under the direct influence of surface water must comply with this paragraph (a) beginning January 1, 2004.”

    40 CFR 141.64, Maximum contaminant levels for disinfection byproducts

  • The BAT for bromate is control of the ozone treatment process to reduce production of bromate.

    “Bromate Control of ozone treatment process to reduce production of bromate”

    40 CFR 141.64, Maximum contaminant levels for disinfection byproducts

  • The 141.64(b)(1) table (the subpart L MCLs) lists TTHM at 0.080 mg/L and HAA5 at 0.060 mg/L. The next two points say how long these subpart L MCLs apply and how the subpart V MCLs are met.

    “Total trihalomethanes (TTHM) 0.080 Haloacetic acids (five) (HAA5) 0.060”

    40 CFR 141.64, Maximum contaminant levels for disinfection byproducts

  • All systems must comply with the subpart L TTHM and HAA5 MCLs in 141.64(b)(1) until the subpart V compliance date in 141.620(c).

    “All systems must comply with these MCLs until the date specified for subpart V compliance in § 141.620(c).”

    40 CFR 141.64, Maximum contaminant levels for disinfection byproducts

  • Beginning on the subpart V compliance date in 141.620(c), the subpart V MCLs for TTHM and HAA5 must be met as a locational running annual average (LRAA) at each monitoring location.

    “The subpart V MCLs for TTHM and HAA5 must be complied with as a locational running annual average at each monitoring location beginning the date specified for subpart V compliance in § 141.620(c).”

    40 CFR 141.64, Maximum contaminant levels for disinfection byproducts

Maximum residual disinfectant levels

  • The MRDL for chloramines is 4.0 mg/L (as Cl2) and for chlorine dioxide 0.8 mg/L (as ClO2).

    “Chloramines 4.0 (as Cl2). Chlorine dioxide 0.8 (as ClO2).”

    40 CFR 141.65, Maximum residual disinfectant levels

  • For CWSs and NTNCWSs, subpart H systems serving 10,000 or more persons had to comply beginning January 1, 2002; subpart H systems serving fewer than 10,000 persons and systems using only ground water not under the direct influence of surface water, beginning January 1, 2004.

    “CWSs and NTNCWSs. Subpart H systems serving 10,000 or more persons must comply with this section beginning January 1, 2002. Subpart H systems serving fewer than 10,000 persons and systems using only ground water not under the direct influence of surface water must comply with this subpart beginning January 1, 2004.”

    40 CFR 141.65, Maximum residual disinfectant levels

  • Transient non-community subpart H systems serving 10,000 or more persons that use chlorine dioxide as a disinfectant or oxidant had to comply with the chlorine dioxide MRDL beginning January 1, 2002.

    “Transient NCWSs. Subpart H systems serving 10,000 or more persons and using chlorine dioxide as a disinfectant or oxidant must comply with the chlorine dioxide MRDL beginning January 1, 2002.”

    40 CFR 141.65, Maximum residual disinfectant levels

  • The BAT for the MRDLs is control of treatment processes to reduce disinfectant demand and control of disinfection treatment processes to reduce disinfectant levels.

    “control of treatment processes to reduce disinfectant demand and control of disinfection treatment processes to reduce disinfectant levels.”

    40 CFR 141.65, Maximum residual disinfectant levels

Radionuclides

  • The MCL for combined radium-226 and radium-228 is 5 pCi/L, found by adding the radium-226 and radium-228 results.

    “The maximum contaminant level for combined radium-226 and radium-228 is 5 pCi/L. The combined radium-226 and radium-228 value is determined by the addition of the results of the analysis for radium-226 and the analysis for radium-228.”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • The gross alpha MCL is 15 pCi/L, including radium-226 but excluding radon and uranium.

    “The maximum contaminant level for gross alpha particle activity (including radium-226 but excluding radon and uranium) is 15 pCi/L.”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • The average annual concentration of beta particle and photon radioactivity from man-made radionuclides must not produce an annual dose equivalent to the total body or any internal organ greater than 4 mrem/year.

    “The average annual concentration of beta particle and photon radioactivity from man-made radionuclides in drinking water must not produce an annual dose equivalent to the total body or any internal organ greater than 4 millirem/year (mrem/year).”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • Except for the radionuclides in table A, the concentration of man-made radionuclides causing a 4 mrem total body or organ dose equivalent must be calculated on the basis of 2 liters per day of drinking water intake, using the 168 hour data list.

    “Except for the radionuclides listed in table A, the concentration of man-made radionuclides causing 4 mrem total body or organ dose equivalents must be calculated on the basis of 2 liter per day drinking water intake using the 168 hour data list”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • If two or more radionuclides are present, the sum of their annual dose equivalent to the total body or to any organ must not exceed 4 mrem/year.

    “If two or more radionuclides are present, the sum of their annual dose equivalent to the total body or to any organ shall not exceed 4 mrem/year.”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • The uranium MCL is 30 µg/L.

    “The maximum contaminant level for uranium is 30 µg/L.”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • Community water systems must comply with the radium, gross alpha, beta/photon and uranium MCLs beginning December 8, 2003, with compliance determined under 141.25 and 141.26.

    “Community water systems must comply with the MCLs listed in paragraphs (b), (c), (d), and (e) of this section beginning December 8, 2003 and compliance shall be determined in accordance with the requirements of §§ 141.25 and 141.26.”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • Table B lists ion exchange, reverse osmosis and lime softening as BAT for combined radium, and adds coagulation/filtration for uranium.

    “1. Combined radium-226 and radium-228 Ion exchange, reverse osmosis, lime softening. 2. Uranium Ion exchange, reverse osmosis, lime softening, coagulation/filtration.”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

  • Table B lists ion exchange and reverse osmosis as BAT for beta particle and photon radioactivity.

    “4. Beta particle and photon radioactivity Ion exchange, reverse osmosis.”

    40 CFR 141.66, Maximum contaminant levels for radionuclides

Sources

Quotes from 40 CFR Part 141 Subpart G are checked against the eCFR text dated November 3, 2026. goraedu does not certify water operators, and our questions are not a state operator certification exam. Not affiliated with or endorsed by the U.S. EPA, any state drinking water program or any operator certification body. Found an error? Tell us.

Other Drinking water operator study guides: Systems and definitions, Total coliform (RTCR), Filtration and disinfection, Disinfectant residuals and byproducts, Lead and copper, Public notification, Secondary standards and lead free plumbing