Forklift operating condition and maintenance study guide

Paragraphs (p) and (q) of 29 CFR 1910.178, OSHA's powered industrial truck standard for general industry, cover the operation of the truck and the maintenance of industrial trucks. This guide sets out what the federal rule text states on taking unsafe trucks out of service, fueling, fuel leaks and open flames, who makes repairs and where, replacement parts, alterations and conversion to LP gas, the examination before trucks are placed in service, mufflers, and cleaning. These two paragraphs are short, so this guide has fewer points than others. Under paragraph (l) of the standard, the employer must make sure its operators are trained and evaluated and must certify that they were; goraedu does none of that, and this is not a certification or operator evaluation. Your State may run its own OSHA-approved plan with its own rules, so check them too. Every point links to the regulation and quotes its exact words.

Fact-checked against official sources · Last checked

Removing unsafe trucks from service

  • Under 1910.178(p)(1), if at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, it shall be taken out of service until it has been restored to safe operating condition.

    “If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.”

    29 CFR 1910.178, Powered industrial trucks

  • Under 1910.178(q)(1), any power-operated industrial truck not in safe operating condition shall be removed from service.

    “Any power-operated industrial truck not in safe operating condition shall be removed from service.”

    29 CFR 1910.178, Powered industrial trucks

  • A vehicle that emits hazardous sparks or flames from the exhaust system shall immediately be removed from service. It is not returned to service until the cause for the emission of such sparks and flames has been eliminated.

    “that emits hazardous sparks or flames from the exhaust system shall immediately be removed from service, and not returned to service until the cause for the emission of such sparks and flames has been eliminated.”

    29 CFR 1910.178, Powered industrial trucks

  • When the temperature of any part of any truck is found to be in excess of its normal operating temperature, thus creating a hazardous condition, the vehicle shall be removed from service.

    “When the temperature of any part of any truck is found to be in excess of its normal operating temperature, thus creating a hazardous condition, the vehicle shall be removed from service”

    29 CFR 1910.178, Powered industrial trucks

  • An overheated vehicle is not returned to service until the cause for such overheating has been eliminated.

    “not returned to service until the cause for such overheating has been eliminated.”

    29 CFR 1910.178, Powered industrial trucks

Fueling, fuel leaks and open flames

  • Fuel tanks shall not be filled while the engine is running.

    “Fuel tanks shall not be filled while the engine is running.”

    29 CFR 1910.178, Powered industrial trucks

  • Spillage shall be avoided.

    “Fuel tanks shall not be filled while the engine is running. Spillage shall be avoided.”

    29 CFR 1910.178, Powered industrial trucks

  • Spillage of oil or fuel shall be carefully washed away or completely evaporated, and the fuel tank cap replaced, before the engine is restarted.

    “Spillage of oil or fuel shall be carefully washed away or completely evaporated and the fuel tank cap replaced before restarting engine.”

    29 CFR 1910.178, Powered industrial trucks

  • No truck shall be operated with a leak in the fuel system until the leak has been corrected.

    “No truck shall be operated with a leak in the fuel system until the leak has been corrected.”

    29 CFR 1910.178, Powered industrial trucks

  • Open flames shall not be used for checking the electrolyte level in storage batteries or the gasoline level in fuel tanks.

    “Open flames shall not be used for checking electrolyte level in storage batteries or gasoline level in fuel tanks.”

    29 CFR 1910.178, Powered industrial trucks

Repairs: who and where

  • All repairs shall be made by authorized personnel.

    “All repairs shall be made by authorized personnel.”

    29 CFR 1910.178, Powered industrial trucks

  • No repairs shall be made in Class I, II, and III locations.

    “No repairs shall be made in Class I, II, and III locations.”

    29 CFR 1910.178, Powered industrial trucks

  • Repairs to the fuel and ignition systems of industrial trucks which involve fire hazards shall be conducted only in locations designated for such repairs.

    “Those repairs to the fuel and ignition systems of industrial trucks which involve fire hazards shall be conducted only in locations designated for such repairs.”

    29 CFR 1910.178, Powered industrial trucks

  • Trucks in need of repairs to the electrical system shall have the battery disconnected prior to such repairs.

    “Trucks in need of repairs to the electrical system shall have the battery disconnected prior to such repairs.”

    29 CFR 1910.178, Powered industrial trucks

Not covered here

The meaning of Class I, II and III locations is not set out in paragraphs (p) and (q) and is not described here. We only write what an official source states, so study these parts with your certifying program's materials.

Parts, alterations and LP conversion

  • Parts requiring replacement shall be replaced only by parts equivalent as to safety with those used in the original design.

    “All parts of any such industrial truck requiring replacement shall be replaced only by parts equivalent as to safety with those used in the original design.”

    29 CFR 1910.178, Powered industrial trucks

  • Industrial trucks shall not be altered so that the relative positions of the various parts are different from what they were when originally received from the manufacturer.

    “Industrial trucks shall not be altered so that the relative positions of the various parts are different from what they were when originally received from the manufacturer”

    29 CFR 1910.178, Powered industrial trucks

  • Nor shall they be altered by the addition of extra parts not provided by the manufacturer or by the elimination of any parts, except as provided in paragraph (q)(12).

    “nor shall they be altered either by the addition of extra parts not provided by the manufacturer or by the elimination of any parts, except as provided in paragraph (q)(12) of this section.”

    29 CFR 1910.178, Powered industrial trucks

  • Additional counterweighting of fork trucks shall not be done unless approved by the truck manufacturer.

    “Additional counterweighting of fork trucks shall not be done unless approved by the truck manufacturer.”

    29 CFR 1910.178, Powered industrial trucks

  • Under (q)(12), trucks originally approved for the use of gasoline for fuel may be converted to liquefied petroleum gas fuel, provided the complete conversion results in a truck which embodies the features specified for LP or LPS designated trucks.

    “Industrial trucks originally approved for the use of gasoline for fuel may be converted to liquefied petroleum gas fuel provided the complete conversion results in a truck which embodies the features specified for LP or LPS designated trucks.”

    29 CFR 1910.178, Powered industrial trucks

  • Such conversion equipment shall be approved.

    “Such conversion equipment shall be approved.”

    29 CFR 1910.178, Powered industrial trucks

  • The description of the component parts of the conversion system and the recommended method of installation on specific trucks are contained in the "Listed by Report."

    “The description of the component parts of this conversion system and the recommended method of installation on specific trucks are contained in the “Listed by Report.””

    29 CFR 1910.178, Powered industrial trucks

Not covered here

The contents of the "Listed by Report" are not described here. We only write what an official source states, so study these parts with your certifying program's materials.

Examination before service

Not covered here

The rule text does not list the items to be examined; no checklist is given here. We only write what an official source states, so study these parts with your certifying program's materials.

Mufflers, cleaning and solvents

  • Water mufflers shall be filled daily or as frequently as is necessary to prevent depletion of the supply of water below 75 percent of the filled capacity.

    “Water mufflers shall be filled daily or as frequently as is necessary to prevent depletion of the supply of water below 75 percent of the filled capacity.”

    29 CFR 1910.178, Powered industrial trucks

  • Vehicles with mufflers having screens or other parts that may become clogged shall not be operated while such screens or parts are clogged.

    “Vehicles with mufflers having screens or other parts that may become clogged shall not be operated while such screens or parts are clogged.”

    29 CFR 1910.178, Powered industrial trucks

  • Industrial trucks shall be kept in a clean condition, free of lint, excess oil, and grease.

    “Industrial trucks shall be kept in a clean condition, free of lint, excess oil, and grease.”

    29 CFR 1910.178, Powered industrial trucks

  • Noncombustible agents should be used for cleaning trucks (the rule says "should").

    “Noncombustible agents should be used for cleaning trucks.”

    29 CFR 1910.178, Powered industrial trucks

  • Low flash point (below 100 °F.) solvents shall not be used.

    “Low flash point (below 100 °F.) solvents shall not be used.”

    29 CFR 1910.178, Powered industrial trucks

  • High flash point (at or above 100 °F.) solvents may be used.

    “High flash point (at or above 100 °F.) solvents may be used.”

    29 CFR 1910.178, Powered industrial trucks

  • Precautions regarding toxicity, ventilation, and fire hazard shall be consonant with the agent or solvent used.

    “Precautions regarding toxicity, ventilation, and fire hazard shall be consonant with the agent or solvent used.”

    29 CFR 1910.178, Powered industrial trucks

Not covered here

Paragraph (q)(11) is reserved. We only write what an official source states, so study these parts with your certifying program's materials.

Sources

Quotes from 29 CFR 1910.178(p) and (q) are checked against the eCFR text dated November 3, 2026. goraedu does not train, evaluate or certify forklift operators, and our questions are not an operator evaluation. Under 29 CFR 1910.178(l) the employer must ensure each operator has completed the required training and evaluation, and certifies that this was done. Not affiliated with or endorsed by OSHA or the U.S. Department of Labor. Found an error? Tell us.